Packaging unit

Piece

Detailed information

Compact electronic flow counter for electrical barrel and container pumps. For thin fluid media.

Typical application area of the product

For fuel oil, diesel, sod. hy­droxide, etc.

  • Flow meter

Specifications

General material

PP
Polypropylene

General material

Hastelloy C
Hastelloy 2.4610, AISI Alloy C-4

General material

PTFE
Polytetrafluoroethylene

Limit values

Viscosity up to:
40

Thread

Thread:
G 1 1/4 Zoll
Version:
Cap nut

Additional thread

Thread:
G 1 1/4 Zoll
Version:
External thread

Operating pressure (at +20 °C)

Pressure max.:
10 bar

Operating temperature

Temperature max.:
50 °C
Temperature min.:
-10 °C

Measuring range

Measuring range from:
5 l/min
Measuring range up to:
120 l/min
To the list of chemical resistance

Viscosity - The right pump for each liquid

When choosing a ­suitable pump several criteria must be considered. The most important are the viscosity, structure and density of the liquid.
Learn more